EVALUASI KINERJA PEMBANGKIT LISTRIK TENAGA SURYA (PLTS) ON-GRID BERBASIS PANEL SURYA MONOCRYSTALLINE DI KOTA PONTIANAK
Kata Kunci:
PLTS On-Grid, Performance Ratio, Tilt Angle, Kinerja Sistem, Kota PontianakAbstrak
Kinerja Pembangkit Listrik Tenaga Surya (PLTS) sangat dipengaruhi oleh kondisi lingkungan geografis dan parameter instalasi fisik, khususnya di wilayah khatulistiwa. Penelitian ini bertujuan untuk menganalisis kinerja sistem PLTS on-grid berkapasitas 3,76 kWp yang menggunakan delapan modul surya monokristalin 470 Wp di Kota Pontianak. Pemantauan dan evaluasi kinerja dilakukan selama 61 hari (Agustus hingga September 2025) dengan berfokus pada parameter Global Tilt Irradiance (H_T), Final Yield (Y_F), Reference Yield (Y_R), Performance Ratio (PR), dan Capacity Utilization Factor (CUF). Metodologi perhitungan parameter tersebut juga secara spesifik memperhitungkan faktor astronomis, geometris, serta nilai albedo permukaan atap seng sebesar 0,20. Hasil evaluasi menunjukkan bahwa sistem menghasilkan nilai Y_F rata-rata sebesar 3,2041 jam/hari dan Y_R sebesar 4,7467 jam/hari. Adapun persentase Performance Ratio (PR) yang dicapai adalah sebesar 68,47% dengan tingkat CUF sebesar 13,35%. Penurunan rasio kinerja sistem dari kondisi ideal diidentifikasi berasal dari akumulasi rugi-rugi (losses) operasional dan lingkungan. Faktor penyumbang penurunan kinerja tersebut meliputi instalasi sudut kemiringan (tilt angle) sebesar 20,25° yang menyimpang curam dari sudut optimal wilayah ekuator (5°), efek bayangan (shading) dari vegetasi di sisi barat pada sore hari, tingginya suhu operasional modul di ekosistem dataran rendah, serta faktor degradasi modul sekitar 1,2% setelah tiga tahun beroperasi. Sebagai langkah optimalisasi, penyesuaian sudut kemiringan modul menjadi lebih landai, pemantauan suhu serta kinerja inverter secara berkala, dan penggunaan periode data pengamatan yang lebih representatif sangat direkomendasikan untuk pengembangan sistem PLTS di masa mendatang.
The performance of Solar Power Plants (PLTS) is highly influenced by geographical environmental conditions and physical installation parameters, particularly in equatorial regions. This study aims to analyze the performance of a 3.76 kWp on-grid PLTS system using eight 470 Wp monocrystalline solar modules in Pontianak City. Performance monitoring and evaluation were conducted over 61 days (August to September 2025), focusing on the parameters of Global Tilt Irradiance (H_T), Final Yield (Y_F), Reference Yield (Y_R), Performance Ratio (PR), and Capacity Utilization Factor (CUF). The calculation methodology for these parameters also specifically accounted for astronomical and geometrical factors, as well as a zinc roof surface albedo value of 0.20. The evaluation results indicate that the system generated an average Y_F of 3.2041 hours/day and a Y_R of 4.7467 hours/day. The achieved Performance Ratio (PR) percentage was 68.47%, with a CUF rate of 13.35%. The system's performance deviation from ideal conditions was identified as originating from an accumulation of operational and environmental losses. The contributing factors to this performance degradation include an installation tilt angle of 20.25°, which steeply deviates from the optimal equatorial angle (5°), shading effects from vegetation on the western side during the afternoon, high operating temperatures of the modules in a lowland ecosystem, and an estimated module degradation of 1.2% after three years of operation. For optimization, adjusting the module tilt angle to be flatter, conducting regular monitoring of temperature and inverter performance, and utilizing a more representative observation data period are highly recommended for future PLTS system development.